Ozone Test - Protect 800
- Authors
- Hamilton Gray, Brian Bielawa, Paul J. Comfort Jr.
- Facility
- Intertek; New York
- Download
- Full Report
Objective
To determine the peak ozone location and measure ozone concentration.
Methodology
Ozone Testing was conducted in accordance to the Standard UL 867 Section 40.
Summary of Results
PASS - Steady-state conditions were reached within 8 hours with maximum ozone concentration measured of 0.017 ppm by volume on the high fan speed setting and 0.020 ppm on the low fan speed setting.
The maximum allowable ozone concentration is 0.050 ppm.